crosslinked cable indoor termination & Joint Kit

 

 

Detail

 

Application:

NRSY-10 series apply to 6/10KV,8.7/15KV crosslinked cable indoor termination

WRSY-10 series apply to 6/10KV,8.715KV crosslinked cable outdoor termination

Features:

a)   Made of liquid silicone rubber, With anti-tear, anti-electric marks, corrosion resistance, excellent electrical properties

b)   Stress control and insulation as a whole, effectively avoid the gap between the layers to reduce the installation steps

c)   The high elasticity of silicone rubber can effectively avoid the shortcomings caused by the respiratory effects of the cable

d)   With constant force springs,no welding

e)   Using red, yellow and green three-color sealed tube, phase identification obvious

f)   No need to fire, easy to install, safe and reliable

 

 

 

 

 

 

Property

Product Model

Property

Standard requirements

Test result

1

1min Power frequency voltage test

45KV,1min, no flashover and no breakdown

Approved

2

Partial discharge test

13Kv, Discharge capacity≤20PC

Approved

3

Constant voltage load cycling test in air

The voltage and conductor temperature are heated to 95℃~100℃,8  hours per cycles, total 3cycle,heat 5hours and cooling 3hours,No breakdown, no flash

Approved

4

impact voltage test

105Kv,10times of the positive and the negativerespectively, No breakdown, no flash

Approved

5

15 minutes negative polarity dc voltage test

-52kv,15 min, No breakdown, no flash

Approved

6

4 hours Power frequency voltage test

35KV,4h , no flashover and no breakdown

Approved

7

Salt spray test for outdoor cable terminal

11KV,1000h,no trip, No visible damage

Approved

8

Humidity test for for indoor cable terminal

11KV,300h,no trip, No visible damage

Approved

 

 

 

 

 

Specification:

Item

Description of goods

Specification

Applicable Section(mm2)

Single core 

indoor cable terminal

NRSY-10/1x0

10-16

indoor cable terminal

NRSY-10/1x1

25-50

indoor cable terminal

NRSY-10/1x2

70-120

indoor cable terminal

NRSY-10/1x3

150-240

indoor cable terminal

NRSY-10/1x4

300-400

indoor cable terminal

NRSY-10/1x5

500-630

Outdoor cable terminal

WRSY -10/1x0

10-16

Outdoor cable terminal

WRSY -10/1x1

25-50

Outdoor cable terminal

WRSY -10/1x2

70-120

Outdoor cable terminal

WRSY -10/1x3

150-240

Outdoor cable terminal

WRSY -10/1x4

300-400

Outdoor cable terminal

WRSY -10/1x5

500-630

Threecore

indoor cable terminal

NRSY-10/3x0

10-16

indoor cable terminal

NRSY-10/3x1

25-50

indoor cable terminal

NRSY-10/3x2

70-120

indoor cable terminal

NRSY-10/3x3

150-240

indoor cable terminal

NRSY-10/3x4

300-400

Outdoor cable terminal

WRSY -10/3x0

10-16

Outdoor cable terminal

WRSY -10/3x1

25-50

Outdoor cable terminal

WRSY -10/3x2

70-120

Outdoor cable terminal

WRSY -10/3x3

150-240

Outdoor cable terminal

WRSY -10/3x4

300-400

【Last】      【Next】      【Return】

Order

Respected customers:
Thank you for browsing our website, please fill in following information, (* is required), and it will be sent via E-mail, we will contact you, thank you!

Your name: *
Company name: *
Address:
Post code:
Country:
Tel: *
Fax:
E-mail: *
Website:
Details: *
Verification code:
   

May be interested product

Information