NLS-15/WLS-15 15kVsilicone rubber cold shrinkage crosslinked cable terminal fitting

 

 

Detail

 

Scope of application
NLS-15 series is suitable for indoor terminal of 6/10kV, 8.7/15kV crosslined cable;
WLS-15 series is suitable for outdoor terminal of 6/10kV, 8.7/15kV crosslinked cable.


Product features
Used of liquid silicon rubber;
Excellent tearing resistance, anti-tracking, anti-corrosion and electric performance;
Integrated of stress control and insulation;
Equipped with constantforce spring and no request of welding;
3 colors of sealing pipe: red, yellow, green;
No need of flame operation;
Simple installation and high safety and reliability;


Main performance

No.

Test item

Standard request

Test results

Evaluation

1

1min power-frequency voltage test

45kV, 1min, no arc-over, no breakdown

45kV, 1min, no arc-over, no breakdown

up to standards

2

partial discharge test

13kV below, discharge capacity is no higher than 20pC

13kV discharge capacity of all phase
2pC, 1.8pC, 1.9pC

up to standards

3

load cycling test

heating to 90°C~95°C, each cycle 8h, 5h for heating and 3h for cooling, ternary cycle for 3 times

Standard request 3 times of load cycling test

up to standards

4

partial discharge test(after load cycling test)

13kV below, discharge capacity is no higher than 20pC

13kV discharge capacity of all phase even at ≤2pC, 1.9pC, 2.0pC

up to standards

5

impulse voltage test

105kV, positive and negative polarity 10times no arc-over, no breakdown

105kV positive and negative polarity 10 times no arc-over, no breakdown

up to standards

6

negative polarity 15min dc voltage test

-52kV, 15minno arc-over, no breakdown

-52kV, 15min, no arc-over, no breakdown

up to standards

7

4h power-frequency voltage test

35kV, 4h, no arc-over, no breakdown

35kV, 4h, no arc-over, no breakdown

up to standards

8

appearance inspection

no crack, no deformation

no crack, no deformation

up to standard

Note: Above test data is provided by Electric power industry electrical equipment quality inspection and test center.

 

NLS-15 series specification                        WLS-15 series specification

Item

Model/Specification

Cable specification
(mm2)

 

Item

Model/Specification

Cable specification
(mm2)

15kVsilicone rubber cold shrinkage
single-core cross-linked cable
indoor terminal

NLS-15/1.1

25-50

 

15kVsilicone rubber cold shrinkage
single-core cross-linked cable
outdoor terminal

WLS-15/1.1

25-50

NLS-15/1.2

70-120

 

WLS-15/1.2

70-120

NLS-15/1.3

150-240

 

WLS-15/1.3

150-240

NLS-15/1.4

300-400

 

WLS-15/1.4

300-400

15kVsilicone rubber cold shrinkage
three-core cross-linked cable
indoor terminal

NLS-15/3.1

25-50

 

15kVsilicone rubber cold shrinkage
three-core cross-linked cable
outdoor terminal

WLS-15/3.1

25-50

NLS-15/3.2

70-120

 

WLS-15/3.2

70-120

NLS-15/3.3

150-240

 

WLS-15/3.3

150-240

NLS-15/3.4

300-400

 

WLS-15/3.4

300-400

【Last】      【Next】      【Return】

Order

Respected customers:
Thank you for browsing our website, please fill in following information, (* is required), and it will be sent via E-mail, we will contact you, thank you!

Your name: *
Company name: *
Address:
Post code:
Country:
Tel: *
Fax:
E-mail: *
Website:
Details: *
Verification code:
   

May be interested product

Information